Sensor vestível e não invasivo para monitoramento contínuo das taxas de bilirrubina em recém-nascidos ictéricos.

dc.contributor.advisorBianchi, Rodrigo Fernandopt_BR
dc.contributor.authorVieira, Marcel Barbosa
dc.contributor.refereeBianchi, Rodrigo Fernandopt_BR
dc.contributor.refereeSantos, Mirela de Castropt_BR
dc.contributor.refereeGomes, Deilton Gonçalvespt_BR
dc.contributor.refereeCoelho, Bruno Nazáriopt_BR
dc.contributor.refereeSavedra, Ranylson Marcello Lealpt_BR
dc.contributor.refereeSilva, Saul Emanuel Delabridapt_BR
dc.date.accessioned2021-12-14T15:45:40Z
dc.date.available2021-12-14T15:45:40Z
dc.date.issued2021pt_BR
dc.descriptionPrograma de Pós-Graduação em Engenharia de Materiais. Departamento de Engenharia Metalúrgica, Escola de Minas, Universidade Federal de Ouro Preto.pt_BR
dc.description.abstractO monitoramento da bilirrubina em recém-nascidos (RN) ictéricos é de extrema importância para o tratamento fototerápico, pois além de garantir que o tratamento está sendo eficaz, ainda pode evitar a evolução da doença rumo a taxas tóxicas. No entanto, para evitar dor e melhorar a eficácia clínica, faz-se necessário o acompanhamento em tempo real desta doença. Neste contexto, o objetivo principal deste trabalho é desenvolver um sensor vestível não invasivo para monitoramento de bilirrubina em recém-nascidos ictéricos. Para tanto, foi desenvolvido um o dispositivo, a partir de uma estrutura transparente, fabricada com silicone, e LEDs (light emitting diode) nas cores azul, vermelho, verde e violeta, além de um LDR (light dependent resistor). A partir desses componentes foi possível montar um dispositivo ótico capaz de analisar as taxas de bilirrubina in vitro. Os resultados obtidos mostram que o dispositivo é eficiente no monitoramento das taxas da bilirrubina, durante o seu processo de degradação, mostrando inclusive a correlação entre os valores medidos no mesmo e os valores obtidos pela leitura no espectrofotômetro UV-Vis. Portanto, os resultados obtidos até o momento, indicam a viabilidade e eficácia do dispositivo para o monitoramento das taxas de bilirrubina in vitro, em tempo real, de forma não invasiva, indolor e ininterrupta, que possibilita um tratamento mais eficiente do RN ictérico, garantindo uma intervenção positiva dos médicos, sempre que houver uma alteração negativa no tratamento do RN.pt_BR
dc.description.abstractenMonitoring bilirubin in jaundiced newborns (NBs) is extremely important for phototherapy treatment, in addition to ensuring that the treatment is being effective, and to prevent the disease from progressing to toxic rates. However, in order to avoid pain and improve clinical efficacy, it is necessary to monitor this disease in real time. In this context, the main objective of this work is to develop a non-invasive wearable sensor for monitoring bilirubin in jaundiced newborns. To this end, a device was developed, from a transparent structure, using silicon, and blue, red, green and violet LEDs (light emitting diode), in addition to an LDR (light dependent resistor). From this, it was possible to assemble an optical device capable of analyzing bilirubin rates in vitro. The results obtained show that the device is efficient in monitoring bilirubin rates, during its degradation process, even showing the correlation between the values measured in it, and the values obtained by reading on the UV-Vis spectrophotometer. Therefore, the results obtained so far, indicate the feasibility and effectiveness of the device for monitoring the rates of bilirubin in vitro, in real time, in a non-invasive, painless, and uninterrupted manner, which will enable a more efficient treatment of NB, ensuring a positive intervention by doctors, whenever there is a negative change in the treatment of NB.pt_BR
dc.identifier.citationVIEIRA, Marcel Barbosa. Sensor vestível e não invasivo para monitoramento contínuo das taxas de bilirrubina em recém-nascidos ictéricos. 2021. 88 f. Dissertação (Mestrado em Engenharia de Materiais) – Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2021.pt_BR
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/14215
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.rights.licenseAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 29/09/2021 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação.pt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectDispositivo vestívelpt_BR
dc.subjectIcterícia neonatalpt_BR
dc.subjectBilirrubinapt_BR
dc.subjectRecém-nascido ictéricopt_BR
dc.subjectNão invasivopt_BR
dc.titleSensor vestível e não invasivo para monitoramento contínuo das taxas de bilirrubina em recém-nascidos ictéricos.pt_BR
dc.typeDissertacaopt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
DISSERTAÇÃO_SensorVestívelInvasivo.pdf
Tamanho:
3.18 MB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: