Desempenho geotécnico de cortinas atirantadas executadas em Cascavel-PR.

dc.contributor.advisorPorto, Thiago Bomjardimpt_BR
dc.contributor.authorOliveira, Thays Car Feliciano de
dc.contributor.refereePorto, Thiago Bomjardimpt_BR
dc.contributor.refereeFerreira, Lucas Deleonpt_BR
dc.contributor.refereeRincent, Jean Jacquespt_BR
dc.date.accessioned2023-09-22T21:03:58Z
dc.date.available2023-09-22T21:03:58Z
dc.date.issued2023pt_BR
dc.descriptionPrograma de Pós-Graduação em Engenharia Geotécnica. Núcleo de Geotecnia, Escola de Minas, Universidade Federal de Ouro Preto.pt_BR
dc.description.abstractAs estruturas de contenção atirantadas são amplamente utilizadas no cenário nacional, o que inclui o uso de tirantes para fins provisórios, principalmente em escavações de subsolos em regiões urbanas. Verifica-se a deficiência de dados quanto à capacidade de carga dos tirantes, considerando a ampla variabilidade geológico-geotécnica nacional. Assim, este trabalho teve o objetivo de estudar a capacidade de carga de tirantes para o contexto geológico-geotécnico de Cascavel-PR. Para tanto foram utilizados dados de duas obras do município, principalmente quanto a caracterização preliminar por sondagens e a boletins do controle tecnológico dos tirantes. Ademais foram coletadas amostras indeformadas de cada obra, para caracterização complementar mais detalhada dos índices físicos e parâmetros de resistência dos solos. A análise da capacidade de carga última dos tirantes foi realizada por meio de extrapolação matemática, visto que os tirantes eram provisórios e não atingiram a ruptura no procedimento de protensão. Também verificou-se a estabilidade global das cortinas atirantadas, em conjunto com análises de sensibilidade dos parâmetros geotécnicos, para uma avaliação preliminar das estruturas de contenção dos estudos de caso. Os resultados de caracterização indicaram que os maciços estudados eram constituídos por solos argilosos e argilo-siltosos. Encontrou-se uma ampla faixa de capacidade de carga dos tirantes, para a obra 1 de 45 a 97 kN/m e, para a obra 2 de 60 a 103 kN/m. Apesar da variabilidade, os resultados se enquadram em valores previamente apresentados na literatura para solos com caracterização geotécnica semelhante. As cortinas de ambos os estudos de caso apresentaram resultados satisfatórios de fator de segurança (FS) nas análises de estabilidade e a avaliação de sensibilidade indicou que os parâmetros de resistência do maciço são determinantes para o FS. Em suma, os resultados da pesquisa foram satisfatórios para auxiliar em definições básicas e importantes para análises de contenções atirantadas na região de estudo, principalmente quanto a faixas de resistência coerentes para o solo da região e valores de capacidade de carga para os tirantes.pt_BR
dc.description.abstractenAnchored retaining structures are widely used in the national scenario, which includes use of grouted anchors (tieback anchors) for temporary purposes, mainly for underground excavations in urban regions. Data is lacking regarding pullout capacity of the anchors, when the wide national geological-geotechnical variability is considered. Thus, this work aimed to study the anchors pullout capacity for the geological-geotechnical context of Cascavel-PR, Brazil. For this purpose, data from two constructions (with excavation services) of the city were used, especially regarding the soil preliminary characterization (SPT tests) and anchors technological control (pretension bulletins). In addition, undisturbed samples were collected from each construction site, for complementary and more detailed characterization of the soil in terms of physical indices and resistance parameters. The analysis of the pullout capacity of the anchors was performed through mathematical extrapolation since the anchors were temporary and did not reach failure in the prestressing procedure. The global stability of the retaining structures was also verified, with sensitivity analysis of the geotechnical parameters, for a preliminary evaluation of the retaining structures. The characterization results indicated that the studied massifs were constituted by clay and clay-silt soils. A wide range of pullout anchor capacity was obtained, for site 1 from 45 to 97 kN/m and, for site 2 from 60 to 103 kN/m. Despite the variability, the results are in accordance with values previously presented in the literature for soils with a similar geotechnical characterization. The structures of both case studies presented satisfactory results for the safety factor (SF) in the stability analysis and the sensitivity analysis indicated that the soil strength parameters are determinant for the SF. In short, the research results were satisfactory in order to assist with basic and important definitions for anchored retaining walls analysis in the study region, mainly regarding consistent ranges for the resistance of the region’s soil and values of pullout capacity for the anchors.pt_BR
dc.identifier.citationOLIVEIRA, Thays Car Feliciano de. Desempenho geotécnico de cortinas atirantadas executadas em Cascavel-PR. 2023. 233 f. Dissertação (Mestrado Profissional em Engenharia Geotécnica) – Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2023.pt_BR
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/17467
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.rights.licenseAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 04/09/2018 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação.pt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectFundações - engenhariapt_BR
dc.subjectTirantes de rochapt_BR
dc.subjectMecânica do solo - ensaio triaxialpt_BR
dc.subjectEstacaria - engenharia civilpt_BR
dc.titleDesempenho geotécnico de cortinas atirantadas executadas em Cascavel-PR.pt_BR
dc.typeDissertacaopt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
DISSERTAÇÃO_DesempenhoGeotécnicoCortinas.pdf
Tamanho:
21.98 MB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: