Por favor, use este identificador para citar o enlazar este ítem: http://www.repositorio.ufop.br/jspui/handle/123456789/9145
Título : Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements.
Autor : Silva, Marielle Ferreira
Maas, Stefan
Souza, Henor Artur de
Gomes, Adriano Pinto
Palabras clave : Indoor air quality
Post-occupancy evaluation
Residential buildings
Centralized and decentralized mechanical ventilation
Fecha de publicación : 2017
Citación : SILVA, M. F. et al. Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. Energy and Buildings, v. 148, p. 119-127, 2017. Disponível em: <http://www.sciencedirect.com/science/article/pii/S0378778817313968>. Acesso em: 29 set. 2017.
Resumen : Complete knowledge about habits of the occupants, including their opinions regarding ventilation systems is an important condition for reducing the consumption of natural resources and improving indoor comfort. In addition, uncomforted occupants tend to take measures to improve their situation, which may increase energy consumption. Advanced thermal models for buildings can perhaps predict interactions between the IAQ determinants, e.g. energy consumption, ventilation and comfort, but do not take into account the behavior of residents. By questionnaires and physical measurements this study evaluated dwellings equipped partly with centralized and partly with decentralized ventilation systems with heat recovery. This field study involved two post-occupied residential buildings situated in the city of Esch-sur-Alzette, Luxembourg, during spring season 2015. Thus, both the physical measurements and questionnaires were considered. The results obtained demonstrated that more than 80% of the residents were satisfied and the perceived IAQ was judged “normal”, “good” or even “very good”. Further more, the measurements performed detected in some cases malfunction of ventilation devices, wherefore the occupants were unable.
URI : http://www.repositorio.ufop.br/handle/123456789/9145
metadata.dc.identifier.doi: https://doi.org/10.1016/j.enbuild.2017.04.049
ISSN : 0378-7788
Aparece en las colecciones: DECAT - Artigos publicados em periódicos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ARTIGO_PostOccupancyEvaluation.pdf2,7 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.