Título: Experimental analysis of a mechanical shear connector in concrete filled steel tube column.
Título(s) alternativo(s): Análise experimental de um conector mecânico de cisalhamento em pilar misto de aço e concreto.
Autor(es): Ribeiro Neto, Juliano Geraldo
Sarmanho, Arlene Maria Cunha
Palavras-chave: Circular hollow section
Push-out test
Seção tubular circular
Ensaio de cisalhamento direto
Data do documento: 2017
Referência: RIBEIRO NETO, J. G.; SARMANHO, A. M. C. Experimental analysis of a mechanical shear connector in concrete filled steel tube column. Revista IBRACON de Estruturas e Materiais, v. 10, p. 592-625, 2017. Disponível em: <http://www.scielo.br/scielo.php?pid=S1983-41952017000300592&script=sci_abstract>. Acesso em: 29 set. 2017.
Resumo: Este trabalho compreende um estudo analítico e experimental do comportamento estrutural de conectores de cisalhamento em pilares mistos, formados por perfis tubulares laminados de seção circular de aço preenchido por concreto simples. Para este estudo foi adotado um conector do tipo parafuso estrutural, a fim de verificar a validade das expressões analíticas constantes na ABNT NBR 16239:2014 [1]. Foi realizada uma série de ensaios experimentais de cisalhamento direto, fixando o diâmetro externo do tubo e variando a espessura, o diâmetro do parafuso, a resistência do concreto e a presença ou não de folga no furo. Da análise dos resultados observa-se que é viável a utilização desse tipo de conector, que as equações existentes para o dimensionamento dos mesmos estão a favor da segurança e podem ser ajustadas para fornecer valores de capacidade resistente mais próximo do experimental.
Resumo em outra língua: This work includes an analytical and experimental study of the structural behavior of shear connectors in composite columns, composed of concrete-filled circular hollow section. For this study was adopted a structural bolt like a shear connector in order to verify the validity of the analytical expressions in ABNT NBR 16239: 2014 [1]. Was carried out a series of push-out tests, fixing the outer diameter of the hollow section and varying the thickness, the bolt diameter, the strength of concrete and the hole dimension. Analysis of the results shows that is possible to use this type of shear connector. The Brazilian prescriptions results are conservative and may be adjusted to provide strength capacity value closest to the experiment.
URI: http://www.repositorio.ufop.br/handle/123456789/9128
DOI: https://doi.org/10.1590/s1983-41952017000300004
ISSN: 1983-4195
Licença: Os trabalhos publicados na Revista IBRACON de Estruturas e Materiais estão sob Licença Creative Commons que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante. Fonte: Revista IBRACON de Estruturas e Materiais <http://www.scielo.br/scielo.php?script=sci_serial&pid=1983-4195&lng=en&nrm=iso>. Acesso em: 14 jan. 2020.
Aparece nas coleções:DECIV - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_ExperimentalAnalysisMechanical.pdf5,21 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.