Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/4963
Registro completo de metadados
Campo Dublin CoreValorIdioma
dc.contributor.authorSouza, Érica Silva-
dc.contributor.authorMartins, Amarildo Otavio-
dc.contributor.authorFajardo, Humberto Vieira-
dc.contributor.authorProbst, Luiz Fernando Dias-
dc.contributor.authorCarasek, Eduardo-
dc.date.accessioned2015-04-09T10:53:52Z-
dc.date.available2015-04-09T10:53:52Z-
dc.date.issued2008-
dc.identifier.citationSOUZA, E. S. et al. Use of Al2O3 in an automated on-line pre-concentration system for determination of cadmium(II) by FAAS. Journal of Hazardous Materials, v. 150, p. 328-334, 2008. Disponível em: <http://www.sciencedirect.com/science/article/pii/S030438940700605X>. Acesso em: 02 fev. 2015.pt_BR
dc.identifier.issn0304-3894-
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/4963-
dc.description.abstractThis paper presents the development of an on-line pre-concentration system to determine cadmium(II) in aqueous samples. The analyte was trapped in a mini-column filled with Al2O3 in the form of macro-spheres obtained by the mixture of Al(NO3)3•9H2Oaq and chitosan dissolved in acetic acid. The mixture was dropped into an NH4OH aqueous solution under rigorous agitation using a peristaltic pump, the macro-spheres were separated from alkaline solution and dried, and finally were submitted to thermal treatment. The pre-concentration system was linear between 1.0 and 100 _gL−1, with a linearity of 0.999, sensitivity of 3.58×10−3 L_g−1 and enrichment factor of 21.9. The limits of detection and quantification were 0.08 _gL−1 and 0.28 _gL−1, respectively. The repeatability was between 2.6 and 5.9%. Recovery tests were carried out with a real aqueous sample.pt_BR
dc.language.isoen_USpt_BR
dc.subjectAluminapt_BR
dc.subjectPre-concentrationpt_BR
dc.subjectCadmium(II)pt_BR
dc.subjectFlame atomic absorption spectrometrypt_BR
dc.titleUse of Al2O3 in an automated on-line pre-concentration system for determination of cadmium(II) by FAAS.pt_BR
dc.typeArtigo publicado em periodicopt_BR
dc.rights.licenseO periódico Journal of Hazardous Materials concede permissão para depósito deste artigo no Repositório Institucional da UFOP. Número da licença: 3580760578368.pt_BR
dc.identifier.doihttps://doi.org/10.1016/j.jhazmat.2007.04.114-
Aparece nas coleções:DEQUI - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_UseAlO3Automated.pdf885,8 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.