Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/1893
Registro completo de metadados
Campo Dublin CoreValorIdioma
dc.contributor.authorLobo, Fabiana Aparecida-
dc.contributor.authorGoveia, Danielle-
dc.contributor.authorOliveira, Adriana Paiva de-
dc.contributor.authorRomão, Luciane Pimenta Cruz-
dc.contributor.authorFraceto, Leonardo Fernandes-
dc.contributor.authorDias Filho, Newton Luiz-
dc.contributor.authorRosa, André Henrique-
dc.date.accessioned2012-11-29T13:47:25Z-
dc.date.available2012-11-29T13:47:25Z-
dc.date.issued2011-
dc.identifier.citationLOBO, F. A. et al. Development of a method to determine Ni and Cd in biodiesel by graphite furnace atomic absorption spectrometry. Fuel, v. 90, n. 1, p. 142-146, jan. 2011. Disponível em: <https://www.sciencedirect.com/science/article/pii/S0016236110004801>. Acesso em: 29 nov. 2012.pt_BR
dc.identifier.issn00162361-
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/1893-
dc.description.abstractThis paper proposes a low cost, simple, fast method for determining Ni and Cd in biodiesel samples by graphitefurnaceatomicabsorptionspectrometry (GFAAS). The method was evaluated in biodiesel from different sources. Tungsten was used as a permanent modifier and the samples were prepared in the form of microemulsions, by mixing about 0.5 g of biodiesel with 5 g of surfactant (Triton X-100) in volumetric flasks and completing the volume with HNO3 1% (v/v). The detection limits obtained for Ni and Cd in microemulsions were ≤0.9 and 0.1 μg L−1, respectively. The relative standard deviation (% R.S.D., n = 12) was ≤8.20% for Ni (washed animal fat sample) and ≤4.71% for Cd (sunflower oil sample). Accuracy was checked based on addition and recovery experiments, which yielded recovery rates varying from 93% to 108% for Ni and from 98% to 116% for Cd. Sample preparation is rapid and easy, and the use of an inorganic standard for calibration makes this sample preparation procedure suitable for routine applications.pt_BR
dc.language.isoen_USpt_BR
dc.subjectBiodieselpt_BR
dc.subjectAbsorptionspectrometrypt_BR
dc.subjectMicroemulsionspt_BR
dc.subjectMetalspt_BR
dc.titleDevelopment of a method to determine Ni and Cd in biodiesel by graphite furnace atomic absorption spectrometry.pt_BR
dc.typeArtigo publicado em periodicopt_BR
dc.rights.licenseO periódico Fuel concede permissão para depósito deste artigo no Repositório Institucional da UFOP. Número da licença: 3313100414118.-
Aparece nas coleções:DECEA - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_DevelopmentMethodDetermine.pdf176,76 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.