Por favor, use este identificador para citar o enlazar este ítem: http://www.repositorio.ufop.br/jspui/handle/123456789/14453
Título : Arrhythmia classification from single-lead ECG signals using the inter-patient paradigm.
Autor : Dias, Felipe Meneguitti
Monteiro, Henrique Luis Moreira
Cabral, Thales Wulfert
Naji, Rayen
Kuehni, Michael
Luz, Eduardo José da Silva
Palabras clave : Electrocardiogram
Machine learning
Segmentation error
Jitter
Fecha de publicación : 2021
Citación : DIAS, F. M. et al. Arrhythmia classification from single-lead ECG signals using the inter-patient paradigm. Computer Methods and Programs in Biomedicine, v. 1, artigo 105948, 2021. Disponível em: <https://www.sciencedirect.com/science/article/abs/pii/S0169260721000225>. Acesso em: 25 ago. 2021.
Resumen : Background and objectives: Arrhythmia is a heart disease characterized by the change in the regularity of the heartbeat. Since this disorder can occur sporadically, Holter devices are used for continuous long-term monitoring of the subject’s electrocardiogram (ECG). In this process, a large volume of data is generated. Consequently, the use of an automated system for detecting arrhythmias is highly desirable. In this work, an automated system for classifying arrhythmias using single-lead ECG signals is proposed. Methods: The proposed system uses a combination of three groups of features: RR intervals, signal morphology, and higher-order statistics. To validate the method, the MIT-BIH database was employed using the inter-patient paradigm. Besides, the robustness of the system against segmentation errors was tested by adding jitter to the R-wave positions given by the MIT-BIH database. Additionally, each group of features had its robustness against segmentation error tested as well. Results: The experimental results of the proposed classification system with jitter show that the sensitivities for the classes N, S, and V are 93.7, 89.7, and 87.9, respectively. Also, the corresponding positive predictive values are 99.2, 36.8, and 93.9, respectively. Conclusions: The proposed method was able to outperform several state-of-the-art methods, even though the R-wave position was synthetically corrupted by added jitter. The obtained results show that our approach can be employed in real scenarios where segmentation errors and the inter-patient paradigm are present.
URI : http://www.repositorio.ufop.br/jspui/handle/123456789/14453
metadata.dc.identifier.uri2: https://www.sciencedirect.com/science/article/abs/pii/S0169260721000225
metadata.dc.identifier.doi: https://doi.org/10.1016/j.cmpb.2021.105948
ISSN : 0169-2607
Aparece en las colecciones: DECOM - Artigos publicados em periódicos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ARTIGO_ArrhythmiaClassificationSingle.pdf
  Restricted Access
880,55 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.