Por favor, use este identificador para citar o enlazar este ítem:
http://www.repositorio.ufop.br/jspui/handle/123456789/14453
Título : | Arrhythmia classification from single-lead ECG signals using the inter-patient paradigm. |
Autor : | Dias, Felipe Meneguitti Monteiro, Henrique Luis Moreira Cabral, Thales Wulfert Naji, Rayen Kuehni, Michael Luz, Eduardo José da Silva |
Palabras clave : | Electrocardiogram Machine learning Segmentation error Jitter |
Fecha de publicación : | 2021 |
Citación : | DIAS, F. M. et al. Arrhythmia classification from single-lead ECG signals using the inter-patient paradigm. Computer Methods and Programs in Biomedicine, v. 1, artigo 105948, 2021. Disponível em: <https://www.sciencedirect.com/science/article/abs/pii/S0169260721000225>. Acesso em: 25 ago. 2021. |
Resumen : | Background and objectives: Arrhythmia is a heart disease characterized by the change in the regularity of the heartbeat. Since this disorder can occur sporadically, Holter devices are used for continuous long-term monitoring of the subject’s electrocardiogram (ECG). In this process, a large volume of data is generated. Consequently, the use of an automated system for detecting arrhythmias is highly desirable. In this work, an automated system for classifying arrhythmias using single-lead ECG signals is proposed. Methods: The proposed system uses a combination of three groups of features: RR intervals, signal morphology, and higher-order statistics. To validate the method, the MIT-BIH database was employed using the inter-patient paradigm. Besides, the robustness of the system against segmentation errors was tested by adding jitter to the R-wave positions given by the MIT-BIH database. Additionally, each group of features had its robustness against segmentation error tested as well. Results: The experimental results of the proposed classification system with jitter show that the sensitivities for the classes N, S, and V are 93.7, 89.7, and 87.9, respectively. Also, the corresponding positive predictive values are 99.2, 36.8, and 93.9, respectively. Conclusions: The proposed method was able to outperform several state-of-the-art methods, even though the R-wave position was synthetically corrupted by added jitter. The obtained results show that our approach can be employed in real scenarios where segmentation errors and the inter-patient paradigm are present. |
URI : | http://www.repositorio.ufop.br/jspui/handle/123456789/14453 |
metadata.dc.identifier.uri2: | https://www.sciencedirect.com/science/article/abs/pii/S0169260721000225 |
metadata.dc.identifier.doi: | https://doi.org/10.1016/j.cmpb.2021.105948 |
ISSN : | 0169-2607 |
Aparece en las colecciones: | DECOM - Artigos publicados em periódicos |