Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/12879
Título: Remoção da interferência de 60 hz no sinal de ECG usando filtro notch digital.
Título(s) alternativo(s): Removal of 60 Hz interference on the ECG signal using digital notch filter.
Autor(es): Barbosa, Gustavo Vinícius Duarte
Baracho, Francisco Ricardo Abrantes Couy
Santos, José Ronaldo Tavares
Damião, Laerty João dos Santos
Palavras-chave: Amplificador de ECG
MATLAB
Interferência eletromagnética
Data do documento: 2019
Referência: BARBOSA, G. V. D. et al. Remoção da interferência de 60 hz no sinal de ECG usando filtro notch digital. Brazilian Journal of Development, Curitiba, v. 5, n. 7, p. 8725-8736, jul. 2019. Disponível em: <http://www.brazilianjournals.com/index.php/BRJD/article/view/2295>. Acesso em: 10 mar. 2020.
Resumo: A interferência de 60 Hz AC pode ser um problema em qualquer situação de medição de biopotencial. A fonte dessa interferência é o potencial AC da rede de alimentação de energia elétrica que está inevitavelmente presente em qualquer situação clínica, ou para iluminação do ambiente ou como fonte de suprimento dos equipamentos de medição. A interferência causada pela rede elétrica, em 60 Hz, pode ser difícil de detectar visualmente em sinais tendo formas de onda não-regulares, como o EEG ou o EMG. Não obstante, a interferência é facilmente visível quando presente em sinais com formas de onda bem definidas, como é o caso do sinal de ECG (Eletrocardiograma). Em todo caso, o espectro de potência do sinal deve fornecer uma indicação clara da presença da interferência da rede como um impulso em 60 Hz. Os harmônicos, caso presentes, aparecem como impulsos adicionais em múltiplos inteiros da frequência fundamental. Neste trabalho é demonstrada uma técnica de filtragem, empregando um filtro “Notch” digital, o qual remove o artefato de 60 Hz do sinal de ECG, aumentando a confiabilidade do diagnóstico clínico a partir da interpretação do mesmo.
Resumo em outra língua: 60 Hz AC interference can be a problem in any biopotential measurement situation. The source of such interference is the AC potential of the electrical power supply network that is inevitably present in any clinical situation, either for lighting the environment or as a source of supply for the measuring equipment. Electrical interference at 60 Hz can be difficult to detect visually on signals having non-regular waveforms such as EEG or EMG. Nevertheless, the interference is easily visible when present in signals with well-defined waveforms, such as the ECG (Electrocardiogram) signal. In any case, the power spectrum of the signal shall provide a clear indication of the presence of the network interference as a 60 Hz pulse. The harmonics, if present, appear as additional pulses in integral multiples of the fundamental frequency. In this work, a filtering technique is demonstrated, using a digital Notch filter, which removes the 60 Hz artifact from the ECG signal, increasing the reliability of the clinical diagnosis from its interpretation.
URI: http://www.repositorio.ufop.br/handle/123456789/12879
DOI: https://doi.org/10.34117/bjdv5n7-082
ISSN: 2525-8761
Licença: O periódico Brazilian Journal of Development permite o depósito das versões pré-print e pós-print de um artigo. Permite remixagem, adaptação e nova criação a partir da obra para fins não comerciais desde que seja atribuído o crédito ao autor (CC BY-NC). Fonte: Diadorim <http://diadorim.ibict.br/handle/1/1253>. Acesso em: 18 maio 2020.
Aparece nas coleções:DEELT - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_RemoçãoInterferência60.pdf974,82 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.