Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/12306
Registro completo de metadados
Campo Dublin CoreValorIdioma
dc.contributor.authorAssis, Roberta Condé de-
dc.contributor.authorFaria, Betania Aparecida de Araujo-
dc.contributor.authorCaldeira, Cláudia Lima-
dc.contributor.authorMageste, Aparecida Barbosa-
dc.contributor.authorLemos, Leandro Rodrigues de-
dc.contributor.authorRodrigues, Guilherme Dias-
dc.date.accessioned2020-06-04T17:31:18Z-
dc.date.available2020-06-04T17:31:18Z-
dc.date.issued2019-
dc.identifier.citationASSIS. R. C. de et al. Extraction of arsenic(III) in aqueous two-phase systems: a new methodology for determination and speciation analysis of inorganic arsenic. Microchemical Journal, v. 147, p. 429-436, jun. 2019. Disponível em: <https://www.sciencedirect.com/science/article/pii/S0026265X18309251>. Acesso em: 10 fev. 2020.pt_BR
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/12306-
dc.description.abstractThis work utilizes the liquid–liquid extraction technique of aqueous two-phase systems (ATPS) formed by a polymer and electrolyte to develop a novel methodology for the extraction, determination, and speciation analysis of inorganic arsenic. To optimize the methodology, the following parameters were studied: pH of the system, nature of the ATPS-forming electrolyte and the polymer, tie-line length (TLL) of the system, type and concentration of extractants, and the mass ratio of the top and bottom phases. The highest extraction (%E = 98%) was obtained for an ATPS composed of L64 + Na2SO4 + H2O, at pH = 6.00, TLL = 33.55% w/w using the ammonium pyrrolidine dithiocarbamate (APDC) extractant in a molar ratio (APDC/As(III)) of 960, and with a mass ratio of 1/4. In these same conditions, As(V) was not extracted satisfactorily (%E = 18%) to ATPS top phase, with a separation factor equal to 530 after three extractions, showing the great potential of the system for the speciation analysis of inorganic arsenic. Moreover, the method was validated employing HG-ICP OES with a coefficient of determination of 0.9957 and limits of detection and quantification equal to 0.20 μg kg−1 and 0.66 μg kg−1, respectively, proving that the method is capable of detecting the low concentrations required by legislation. The relative standard deviation (RSD) values varied between 4.88 and 9.45%, and the RSD in inter-day precision was 11.07%, which are in accordance with the limits of the validation guide used by the National Institute of Metrology, Quality and Technology, COD-CGCRE-008. Furthermore, relative error rates ranged from −7.44 to 9.90% and recovery percentages were between 92.6 and 110% for the accuracy studies. This method was also applied in a spiked tap water sample, presenting a recovery value equal to 87.10%.pt_BR
dc.language.isoen_USpt_BR
dc.rightsrestritopt_BR
dc.titleExtraction of arsenic(III) in aqueous two-phase systems : a new methodology for determination and speciation analysis of inorganic arsenic.pt_BR
dc.typeArtigo publicado em periodicopt_BR
dc.identifier.uri2https://www.sciencedirect.com/science/article/pii/S0026265X18309251pt_BR
dc.identifier.doihttps://doi.org/10.1016/j.microc.2019.03.058pt_BR
Aparece nas coleções:DEQUI - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_ExtratcionArsenicAqueous.pdf
  Restricted Access
620,9 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.